Powered Cardiac Thrombectomy and Thromboaspiration Systems

Powered cardiac thrombectomy and thromboaspiration systems use motorized or vacuum-powered technology to provide sustained mechanical aspiration, maintaining constant suction to remove blood clots from coronary arteries.

Product Examples



ProductManufacturer



Indigo® CAT™ RX

The Indigo® CAT™ RX is a continuous aspiration mechanical thrombectomy system from Penumbra, Inc. It is designed to remove fresh, soft blood clots from coronary and peripheral blood vessels. The system works with the Penumbra ENGINE™ to provide powerful, continuous vacuum aspiration.

The price for a single Penumbra Indigo® CAT™ RX aspiration catheter kit generally ranges from approximately $1,000 to over $4,000, depending on the vendor and whether it is a new or used/resold item. The separate Penumbra ENGINE™ system, which powers the catheter, costs significantly more.
Note that these prices are for the disposable catheter kit used in a single procedure and do not include the cost of the main Aspiration Engine unit or overall hospital procedural costs. Procedural costs can average over $11,000 in a hospital setting, as noted in a 2014 study.
Penumbra Inc.
Street Address: 1310 Harbor Bay Parkway, Alameda, CA 94502, USA
Mailing Address: One Penumbra Place, Alameda, CA 94502, USA


AngioJet™ Peripheral Thrombectomy System

The AngioJet™ Peripheral Thrombectomy System by Boston Scientific is a pharmacomechanical device used to treat blood clots in the peripheral vasculature. It utilizes high-velocity saline jets to fragment and remove thrombi while simultaneously delivering clot-dissolving medications if needed.

Indications:
– Peripheral Arteries: Rapidly restores flow in vessels as small as 1.5 mm.
– Deep Vein Thrombosis (DVT): Treats large clot burdens in iliofemoral and upper/lower extremity veins.
– AV Access: Clears clots in dialysis fistulas and synthetic grafts.

The price for the AngioJet™ Peripheral Thrombectomy System varies significantly between the reusable console and the disposable catheters, with catheters ranging from roughly $1,400 to over $21,000 each, and used consoles available for hundreds to thousands of dollars.
Boston Scientific
300 Boston Scientific Way, Marlborough, MA 01752

The AngioVac System

The AngioVac System (AngioDynamics) is a specialized endovascular aspiration system used to remove large-volume intravascular materials, such as soft thrombi, emboli, or vegetations.

Indications:
Right-Sided Heart Masses: Removal of thrombi or vegetations in the right atrium or right ventricle.

Infective Endocarditis: Debulking of vegetations on the tricuspid valve or cardiac leads (e.g., pacemakers) to reduce bacterial burden in high-risk surgical patients.

Caval Thromboembolism: Clearing clots in the superior and inferior vena cava (IVC).
Pulmonary Embolism (PE): Removal of large, soft emboli from the pulmonary arteries.
AngioDynamics, Inc
Address: 14 Plaza Drive, Latham, New York, 12110, United States.
Phone Number: +1 (518) 798-1215


The FlowTriever System

The FlowTriever System is the first mechanical thrombectomy device FDA-cleared specifically for the treatment of acute pulmonary embolism (PE). It is designed to rapidly remove large clot burdens from the pulmonary arteries without the use of thrombolytic (“clot-busting”) drugs
Indications:
Intermediate and High-Risk PE: Indicated for patients with significant right heart strain (elevated RV/LV ratio) or hemodynamic instability.

Clot-in-Transit: Indicated for the removal of moving thrombi in the right atrium (typically used with Triever catheters alone for this purpose).

Thrombolysis Contraindications: Particularly useful for patients at high risk of bleeding (e.g., recent surgery, stroke) where traditional clot-busters are unsafe.

The cost of the FlowTriever System varies depending on the specific components and the purchasing agreement with the hospital, with individual components ranging from approximately $800 to over $11,000 for the main retrieval catheters. Inari Medical often uses a “Price Per Procedure” (PPP) model for hospitals

Inari Medical
6001 Oak Canyon, Suite 100, Irvine, CA 92618, United States

Free References:


Mechanical Power Aspiration With the Indigo® System: Rethinking Clot Removal


Indigo Thrombectomy System for Hepatic Artery Thrombosis After Liver Transplantation: A Case Report


Effectiveness and Safety of Percutaneous Thrombectomy Devices: Comparison of Rotarex and Angiojet in a Physiological Circulation Model


Thrombectomy Device for Deep Vein Thrombosis


Procedural outcomes associated with use of the AngioVac System for right heart thrombi: A safety report from RAPID registry data


AngioVac System for Infective Endocarditis: A New Treatment for an Old Disease


Management of inferior vena cava thrombosis with the FlowTriever and ClotTriever systems


Catheter-directed therapy with the FlowTriever system for intermediate-high and high-risk pulmonary embolism: a single-centre experience

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *