The Candela GentleLase Pro-U is an aesthetic laser system manufactured by Candela Medical that operates primarily at a 755 nm Alexandrite wavelength. It is widely used in dermatology and medical aesthetics for permanent hair reduction, pigmented lesions, and vascular treatments, and can be upgraded into a dual-wavelength GentleMax Pro system by adding a 1064 nm Nd:YAG module.
Key Clinical Applications
- Permanent Hair Reduction. The 755 nm wavelength is highly absorbed by melanin, making it effective for reducing thin, medium, and thick hair primarily on lighter to medium skin tones (Fitzpatrick skin types IโIII, and cautiously IV).
- Pigmented Lesions. It targets benign epidermal pigmentation such as sun spots, age spots, freckles, and melasma.
- Vascular Lesions and Skin Rejuvenation. The system treats superficial vascular conditions like facial veins, spider veins, angiomas, and port wine stains, while also stimulating collagen to soften fine wrinkles.
Technical Specifications and Features
- Wavelength and Upgradeability. It ships standard as a 755 nm Alexandrite laser (delivering up to 53 J of energy) and features an upgradeable architecture (“Pro-U”) to add a 1064 nm Nd:YAG laser for treating darker skin tones (Fitzpatrick types IVโVI) and deeper vascular issues.
- Spot Sizes and Speed. According to the GentleLase Pro-U Brochure, it supports spot sizes ranging from 1.5 mm up to large 20 mm, 22 mm, and 24 mm delivery handpieces with repetition rates of 2 Hz to 10 Hz for rapid full-body sessions.
- Dynamic Cooling Device (DCD). A patented cryogen spray cools the upper layer of the skin milliseconds before each laser pulse to protect the epidermis and minimize discomfort without needing messy gels.
- Variable Pulse Duration. Pulse widths range from 0.250 ms to 100 ms, allowing practitioners to customize energy delivery for different hair thicknesses and vascular targets.
Patient Experience vs. Clinic Purchasing
- For Patients. Treatments are notably fast and do not require ultrasound gel when DCD cryogen cooling is used, though the laser feels like a brief, cold snap against the skin. Because the 755 nm wavelength strongly targets melanin, patients with darker skin tones (Fitzpatrick IVโVI) generally require the 1064 nm Nd:YAG wavelength to avoid hyperpigmentation or burns.
- For Clinics. The “U” designation stands for upgradeable, allowing practices to purchase the base 755 nm Alexandrite unit and later expand its capabilities to a full GentleMax Pro without replacing the entire console.
Pricing and Availability
New Candela GentleLase Pro-U systems are sold exclusively through direct quotes from Candela Medical and its authorized regional distributors rather than public retail price lists. On the secondary and refurbished medical equipment market across Europe and the US, verified units typically list between $34,000 and $78,000 USD (roughly โฌ34,000 to โฌ49,300 EUR in Europe), depending on manufacture year, pulse count, and included handpieces.
Pricing Breakdown (New vs. Pre-Owned)
Because Candela restricts public MSRP listings for new clinical devices, transparent pricing primarily comes from certified pre-owned and secondary medical marketplaces:
- New Systems (US & Europe). Direct purchases from Candela or authorized partners require a custom quote and frequently include shipping, installation, clinical training, and warranty packages.
- European Secondary Market Listings. According to Bimedis and Remma, used and refurbished units in Europe show the following pricing:
- A 2016 used unit in working condition is listed at โฌ47,065 (excl. VAT) on Remma.
- A 2017 used unit in Spain is listed at $34,088 USD on Bimedis.
- A 2019 unit (Used – Like New) in Slovakia is listed at $40,136 USD on Bimedis.
- A 2023 unit (Used – Good) in Italy is listed at $49,307 USD on Bimedis.
- A 2024 unit (Used – Like New) is listed at $53,881 USD, while a 2023 unit in Greece reaches $78,072 USD on Bimedis.
- US Secondary Market Listings. Pre-owned Candela GentleLase Pro and Pro-U systems on US equipment exchanges such as DOTmed and Machinio generally range from $26,557 to $50,071 USD depending on age and refurbishment status.
Availability in Europe and the United States
- United States. Candela maintains direct corporate offices and sales teams in the US via Candela Medical. Refurbished units with inspection warranties and financing are also available through US aesthetic laser resellers such as The Laser Agent.
- Europe (Direct & Authorized Distributors). Candela operates direct corporate offices in Germany, Spain, France, the United Kingdom, and Ireland. In neighboring European and Balkan markets (including Croatia, Serbia, Slovenia, and Montenegro), sales and technical servicing are handled through authorized regional distributors listed in the Candela Distributor Directory (such as Dalton Medical in the Benelux region or CPO Innova in Greece).
- Cross-Border European Marketplaces. Clinics sourcing refurbished systems across Europe can browse active inventory with international shipping through Bimedis and doc-market.
Important Purchasing Considerations
- Recertification and Service Fees. Buying a used unit outside of Candela’s direct network often requires paying a manufacturer recertification fee before Candela will supply replacement parts, cryogen canisters, or service contracts.
- Included Handpieces and Shot Count. Final pricing varies significantly depending on whether large spot-size delivery systems (18 mm, 20 mm, 22 mm, or 24 mm) and the 1064 nm Nd:YAG upgrade module are already installed.
Leave a Reply