Abre™ venous self-expanding stent system

The Abre™ venous self-expanding stent system, manufactured by Medtronic, is a dedicated peripheral vascular stent designed to treat symptomatic iliofemoral venous outflow obstruction (deep venous obstruction). It received CE Mark approval in April 2017 and U.S. FDA approval in October 2020.

Design & Technical Specifications

  • Stent Architecture. Laser-cut from a single seamless nickel-titanium alloy (nitinol) tube into an open-cell lattice design. Three offset connection points per circumference provide flexibility and kink resistance across mobile anatomy like the inguinal ligament.
  • Radiopaque Markers. Three integral nitinol markers are located at both the cranial and caudal ends to assist with fluoroscopic visualization.
  • Size Matrix. Available in stent diameters ranging from 10 mm to 20 mm and lengths from 40 mm to 150 mm, engineered to maintain uniform radial strength across all sizes.
  • Delivery System. Premounted on an over-the-wire, 9 Fr triaxial shaft catheter compatible with a 0.035-inch guidewire. The ergonomic handle uses a rotating thumbwheel with a locking pin to control friction and prevent stent jumping during placement.

Clinical Indications & Performance

  • Primary Indications. Approved for permanent implantation in the iliofemoral veins to restore blood flow in conditions such as acute deep vein thrombosis (DVT), post-thrombotic syndrome (PTS), and non-thrombotic iliac vein lesions like May-Thurner syndrome.
  • Patency Rates. In the pivotal ABRE Clinical Study, overall primary patency reached 88.0% at 12 months and 81.6% at 36 months. At 36 months, primary patency was 97.1% for non-thrombotic lesions, 76.5% for acute DVT, and 70.4% for post-thrombotic syndrome.
  • Durability. The study reported zero stent fractures and zero stent migrations through 36 months, aligning with 50-year simulated hip flexion bench testing.

Contraindications & Safety Considerations

  • Contraindications. Per the FDA Device Labeling, the system must not be used in patients with known hypersensitivity to nitinol, lesions that prevent full balloon inflation or proper stent placement, or contraindications to anticoagulant or antiplatelet therapy.
  • Potential Adverse Events. Risks include stent thrombosis or occlusion, vessel dissection or perforation, bleeding, hematoma, access site infection, and stent malposition or migration.
  • Regulatory Notice. In January 2026, the FDA issued a Class 2 Device Recall for specific lots due to a nitinol anomaly that could cause reduced deployed stent diameter and radial force.

Pricing and Availability

The Abre™ venous self-expanding stent system is sold exclusively to licensed hospitals, clinics, and authorized medical distributors rather than directly to consumers. Hospital contract pricing typically falls between $1,350 and $2,250 USD (โ‚ฌ1,300 to โ‚ฌ2,100) per unit depending on institutional volume agreements and regional tenders.

Pricing Overview

  • Hospital & Secondary Market Pricing. In-date clinical units on third-party medical supply exchanges such as Synergy Surgical and DOTmed list between $1,395 and $2,238 USD per single-stent box.
  • International Reimbursement Benchmarks. Published healthcare reimbursement schedules, such as the Australian Prescribed List, set the minimum benefit benchmark at A$1,394.00 (approx. $900โ€“$950 USD). European B2B medical marketplaces list units around โ‚ฌ1,373.50 excluding VAT.
  • Non-Clinical / Training Units. Expired units restricted strictly to veterinary, bench testing, or physician training use are sold by resellers like Medical Materials for $350 to $850 USD.

Availability & Ordering Channels

  • Regulatory Clearance. The device holds active CE Mark approval across Europe and FDA Premarket Approval (PMA) in the United States, making it commercially available across major global markets.
  • Catalog & Ordering Codes. European orders use the AB9G prefix (e.g., AB9G14100090 for a 14 mm ร— 100 mm stent on a 90 cm shaft) via the Medtronic Europe Catalog, whereas U.S. orders use the AB9U prefix.
  • Lot Verification. Due to the January 2026 FDA Class 2 Recall affecting specific manufacturing lots, procurement teams should verify lot numbers with Medtronic prior to accepting stock from third-party distributors.

References


Pivotal Study Evaluating the Safety and Effectiveness of the Abre Venous Self-Expanding Stent System in Patients With Symptomatic Iliofemoral Venous Outflow Obstruction