The Medtronic autoLog IQ™ autotransfusion system is a compact, automated cell salvage device designed to collect, concentrate, wash, and reinfuse a patient’s own blood during and after surgery.
. It uses dynamic cell salvage technology to deliver high-hematocrit packed red blood cells with minimal operator intervention.
Core Technology & Features
- Dynamic Cell Salvage. Algorithm-driven blood sensing makes micro-adjustments during processing to maximize red blood cell recovery without manual intervention.
- Intellipath™ Bowl. A single universal bowl size works across most surgical procedures, simplifying inventory and setup.
- Adaptive Two-Stage Fill. The centrifuge initially fills, pauses to compact red blood cells, and adjusts the second fill speed based on hematocrit levels to reduce waste.
- Pulse Wash. Indentations inside the bowl disrupt the red blood cell pack during washing, optimizing saline penetration using only 250 mL of wash solution per cycle.
- Automated Self-Start. Processing begins automatically once roughly 800 mL of blood is detected in the reservoir. If a full bowl is not achieved, the system automatically returns the contents to the reservoir if no manual action is taken.
- Compact & Quiet Design. It features a 7-inch touchscreen, an onboard whisper-quiet vacuum, a vertical manifold for easier installation, and a fold-away handle for tight operating rooms.
Clinical Applications & Performance
- Surgical Specialties. Approved for general, cardiovascular, orthopedic, vascular, plastic/reconstructive, obstetric/gynecologic, and neurological surgeries, as well as postoperative recovery areas.
- Blood Product Quality. Delivers a washed hematocrit of 59% to 65%.
- Contaminant Removal. Achieves 98% heparin washout and 99% fat removal.
- Processing Speed. Completes a standard wash cycle in approximately 1.45 to 3.4 minutes.
Technical Specifications
- Dimensions & Weight. Measures 69 x 80.5 x 42.5 cm and weighs 50 kg.
- Centrifuge & Pump. Centrifuge operates up to 10,000 rpm, and the fluid pump runs up to 1,000 mL/min.
- Data & Power. Stores up to 100 patient records and operates on 100โ240 V power.
Safety & Risks
As with all intraoperative autotransfusion devices, potential clinical risks include hemolysis, air emboli, infection, hemodynamic instability, renal failure, and organ dysfunction.
Pricing and Availability
The Medtronic autoLog IQ™ is commercially available in both the United States and Europe. Because Medtronic sells primary capital equipment directly to healthcare facilities through negotiated institutional contracts, list prices for new consoles are not publicly disclosed, though consumable prices and secondary market rates provide clear benchmarks.
Regional Availability & Model Numbers
Medtronic distributes region-specific hardware configurations to match local electrical and regulatory standards:
- United States (
ATLGIQ). Cleared under FDA 510(k) K181954 for sale by or on the order of a physician. Available directly through Medtronic Perfusion Systems and authorized US hospital distributors. - Europe (
ATLGIQ1/PN-ATLG220). CE-marked and available across the European Economic Area and UK via regional Medtronic Europe offices and authorized medical distributors. ThePN-ATLG220variant is configured for 220 VAC power grids.
Pricing Overview
- New Console Pricing. Medtronic uses custom hospital quotes, volume-based Group Purchasing Organization (GPO) contracts, and reagent-rental agreements (where consoles are placed at low or no upfront cost in exchange for a multi-year consumables commitment). Contacting a regional Medtronic representative is required for an institutional quote.
- Consumables & Disposables. Ongoing procedural kits are sold through medical supply distributors and direct hospital accounts. Retail distributor pricing in the US generally follows these ranges:
- Wash Kit (
ATL2001). Approximately $135 to $220 per kit, or $740 to $1,145 per case of 6 on sites like Grayline Medical and CIA Medical. - One-Source Procedural Packs (
ATLS02/ATLS24). Combined kits containing the wash bowl, suction/anticoagulation line, and hardshell cardiotomy reservoir run roughly $515 to $775 per pack, as listed on MyMapMedical and RPS MedCare. [1, 2, 3, 4]
- Wash Kit (
- Pre-Owned & Refurbished Market. Used units of the earlier-generation Medtronic autoLog (the predecessor console) frequently trade on secondary medical marketplaces like Bimedis for $270 to $2,000 in both the US and Germany. Pre-owned autoLog IQ units appear rarely and command substantially higher prices depending on service history and warranty.